Duminy Designs

ISO Fits & Tolerances Calculator

Hole and shaft limits, deviations and the clearance or interference of any ISO 286 fit, such as H7/g6, H7/k6 or H7/p6, for sizes up to 3150 mm. Type a callout straight off the drawing. Free, metric, no login.

For example 25 H7/g6, Ø40 h6 or 12 P7.

Show
Hole
Shaft
Preferred fits
Check a measured part

Limits from the ISO 286-1 and ISO 286-2 tables of standard tolerances and fundamental deviations. Check critical work against the standard and the drawing.

Preferred fits at Ø25

The ten ISO preferred fits, loosest to tightest, worked out for the size you entered. Click a fit to open it in the calculator.

How it's worked out

A fit callout such as 25 H7/g6 gives the nominal size, the hole class (capital letter) and the shaft class (small letter). The letter places the tolerance zone; the number sets its width.

IT grade
The number (01, 0, 1 to 18) is the standard tolerance grade. Its width in µm comes from the ISO 286-1 table for the size range the nominal size falls in, for example IT7 = 21 µm over 18 up to 30 mm.
Letter
The fundamental deviation: the limit nearest the zero line. H and h sit on it, a to g (A to G) give clearance, j to n are transition, p to zc (P to ZC) give interference.
es, ei / ES, EI
Upper and lower deviation of the shaft / hole. The other limit is the fundamental deviation plus or minus the IT value.
Δ
Holes K, M and N up to IT8 and P to ZC up to IT7 get the Δ correction from the standard, so that H7/p6 and P7/h6 give the same fit.
js, JS
Symmetric about the zero line, ±IT/2.
Max clearance
Largest hole minus smallest shaft (ES − ei).
Min clearance
Smallest hole minus largest shaft (EI − es). A negative clearance is interference.
Fit type
Clearance if the minimum clearance is zero or more, interference if the maximum clearance is zero or less, transition when it can be either.
GO / NO-GO
Plug or ring gauge sizes: GO is the maximum material size (smallest hole, largest shaft), NO-GO the least material size.
Size range
Over 0 up to 3150 mm. a, b, c, cd, ef, fg, j, v to zc and their capitals are only tabulated up to 500 mm or less, as in the standard.

Common questions

What does H7/g6 mean on a drawing?

It is a fit between a hole and a shaft. H7 is the hole class: H puts the lower limit on the nominal size and IT grade 7 sets the tolerance width. g6 is the shaft class: g puts the shaft just under the nominal size, IT6 sets its width. For Ø25 H7/g6 the hole is 25.000 to 25.021 mm and the shaft 24.980 to 24.993 mm, a clearance of 0.007 to 0.041 mm.

What is the difference between a clearance, transition and interference fit?

In a clearance fit the smallest hole is always bigger than the largest shaft (letters a to h on the shaft). In an interference fit the largest hole is always smaller than the smallest shaft (p to zc), so the parts are pressed or shrunk together. A transition fit (j to n) can come out either way, depending on where each part lands in its tolerance.

What is an IT grade?

The number in a class such as H7 is the ISO 286 standard tolerance grade, from IT01 (finest) to IT18. Its width depends on the size range: IT7 is 21 µm over 18 up to 30 mm, IT6 is 13 µm in the same range.

Which ISO fit is used for what?

The common hole-basis fits are H11/c11 loose running, H9/d9 free running, H8/f7 close running, H7/g6 sliding, H7/h6 locational clearance, H7/k6 and H7/n6 locational transition, H7/p6 locational interference, H7/s6 medium drive and H7/u6 force fit. For bearings, use the bearing maker's recommended shaft and housing tolerances.

What size should I machine to?

The calculator gives the mid-limit size, halfway between the upper and lower limit, which leaves the most room either way. GO and NO-GO gauge sizes are the maximum and least material sizes.

Machining it on a lathe or mill?

The free Feeds & Speeds Calculator gives spindle rpm and feed rate for the cut. The full CNC tools, from a lathe program builder to setup sheets made from the G-code, sit behind a client login.